Industrial Measurement Technology for Energy, Process & Machinery – 3-Phase Meters, Panel Instruments & Transmitters

SKU:
TS500-Ex-1R-0
  • Input for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Input intrinsically safe acc. to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD]
  • Switchable line fault detection for broken and shorted lines
  • Output relay SPDT contact
  • Supply voltage 230 VAC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 178,50 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-Ex-1R-5
  • Input for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Input intrinsically safe acc to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD]
  • Switchable line fault detection for broken and shorted lines
  • Output relay SPDT contact
  • Supply voltage 24VDC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 178,50 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-Ex-2R-0
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Inputs intrinsically safe acc to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contacts
  • Supply voltage 230 VAC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 197,54 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-Ex-2R-5
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Inputs intrinsically safe acc. to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD]
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contact>
  • Supply voltage 24VDC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 197,54 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TV500L-110-0
    Item weight:
    0,15 kg
    • full 3-port isolation
    • input: 0/4...20mA and 0/2...10VDC
    • output -20...+20mA and +10...+10VDC
    • increasing output characteristic
    • supply voltage: 230VAC
    • power-on LED
    • 22,5mm case for DIN rail mounting
    Best sellers
    SKU:
    TV500L-110-5
    Item weight:
    0,15 kg
    • full 3-port isolation
    • input: 0/4...20mA and 0/2...10VDC
    • output -20...+20mA and +10...+10VDC
    • increasing output characteristic
    • supply voltage: 24VDC
    • power-on LED
    • 22,5mm case for DIN rail mounting
    SKU:
    TW500ff
    Variations in:
    • Channels
    Item weight:
    0,13 kg
  • 1, 2 or 3 channels
  • High protection acc. German VDE 0110 group 2
  • High accuracy
  • Low voltage drop
  • 22.5mm case for DIN rail mounting
  • SKU:
    ST500-10-0
    Item weight:
    0,11 kg
  • Wide supply voltage range: 100 ... 265V AC
  • Electrically isolated: between input / output / supply voltage
  • 22.5 mm standard case for rail mounting TS35
  • Universal inputs/outputs for (0)4 ... 20 mA and 0(2) ... 10 V
  • 290,36 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    ST500-10-5
    Item weight:
    0,11 kg
  • Supply voltage range: 10.8 ... 30V AC/DC
  • Electrically isolated: between input / output / supply voltage
  • 22.5 mm standard case for rail mounting TS35
  • Universal inputs/outputs for (0)4 ... 20 mA and 0(2) ... 10 V
  • 290,36 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    UT125M
  • Transmitter for electrical signals
  • Universal input for standard signals, Pt100, thermocouple, potentiometer, configuration via front-side DIP switch
  • Analog output 4-20 mA
  • With Pt100 sensors, monitoring of sensor break and short-circuit
  • Wide-range power supply
  • Housing width 12.5 mm
  • Removable coded screw terminals
  • Carrier rail mounting TS35 EN60715
  • 171,36 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TV500-10-ff
    Variations in:
    • Auxiliary Voltage
    Item weight:
    0,20 kg
  • Inputs: 0/4...20mA  or 0/2...10VDC, each selectable 
  • Outputs: 0/4...20mA  or 0/2...10VDC, each selectable 
  • Auxiliary voltage: 100...265VAC or 10.8...30VAC/DC
  • SKU:
    TV125L
  • safe galvanic isolation between input/output/auxiliary voltage
  • step response T90: 40ms
  • output deviation <0.2% of the limit value
  • overload protection of the current input with automatically resetting fuse
  • operating display and status messages via two-colour LED
  • configuration via front DIP switches
  • plug-in terminal strips
  • slim installation width of 12.5mm for carrier rail mounting TS 35
  • 130,90 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    ML2-2ff
    Variations in:
    • Supply Voltage
  • full graphic LCD display 
  • multi-colour backlight (7 colours selectable)
  • universal input for current and voltage standard signals, Pt100, Pt1000, thermocouples or pulses
  • configurable via 4 buttons or via PC software
  • large AC and DC supply voltage ranges
  • Best sellers
    SKU:
    VT500-30-ff
    Variations in:
    • Supply Voltage:
    VT 500-30-, AC Voltage Transmitter
    Best sellers
    SKU:
    RT500ff
    Variations in:
    • Supply Voltage
  • Resistance measuring range from 0 to 50 Ohm up to 100 kOhm 
  • 12 Bit AD/DA processor technology with 250Hz realtime execution 
  • Teach-in programming for initial and final value 
  • 2- and 3-wire connection
  • Outputs for 0/4-20mA, simultaneous 0/2-10V
  • Increase or decrease output characteristic programmable
  • Operation mode indicated by 2-colour LED
  • 22.5mm case for DIN rail mounting
  • SKU:
    WM500ff
    Variations in:
    • Version

    Versions with and without compensating circuits
    Variants for: power supply system 1-or 3-phase; measuring voltage 100/110/230/400 or 440VAC; measuring current 1 or 5AAC; supply voltage 230VAC or 24VDC

    449,82 € - 514,08 € *
    • Available
    You need help?
    Please send a message to priggen@priggen.com

    The “Industrial Measurement Technology” range includes 3-phase power meters, panel instruments for control panels and switchboards, tachometers, limit switches and signal transmitters. These devices allow you to measure, display, monitor and integrate electrical and process values in industrial plants and machinery.

    3-phase meters are used for monitoring and analysing three-phase power systems. They measure, for example, voltages, currents, active, reactive and apparent power, energy, frequency and often harmonic distortion. Typical applications include power distribution, panel building, machine and plant engineering, energy management and power quality monitoring.

    Panel instruments are meters that are permanently mounted in control panels, switchboards or machine fronts. They continuously display key process values such as voltage, current, power, frequency, temperature or pressure and provide quick visual feedback directly at the installation. They are used in power distribution, test benches, machinery and building services.

    Tachometers measure the speed of shafts, motors or fans and are used for process control, regulation or condition monitoring. Limit switches monitor values such as current, voltage, temperature or speed for upper or lower thresholds and activate relay or alarm outputs when limits are reached, helping to protect equipment and trigger warning

    Transmitters convert sensor signals – for example from current transformers, voltage inputs, temperature probes or process signals – into standardised output signals (such as 0…10 V, 4…20 mA or digital interfaces like RS-485/Modbus). These can then easily be fed into PLCs, controllers, SCADA systems or data loggers. Transmitters thus form the key link between field sensors and automation systems.

    Our products are used in industry, power utilities, machine and plant engineering, building services, test benches, laboratories and infrastructure/utilities. Typical applications include monitoring power systems, energy and load measurement, process monitoring, condition monitoring, panel and machine indication as well as integrating process values into control and SCADA systems.

    Yes. Many 3-phase meters, panel instruments and transmitters provide analogue outputs (e.g. 4…20 mA, 0…10 V) and/or digital interfaces such as RS-485/Modbus. This makes it easy to integrate measurement values into PLCs, SCADA systems, building management and data logging solutions. The technical data sheets specify which interfaces and protocols are supported.

    Yes, absolutely. If you tell us about your application, target parameters (e.g. voltage, current, power, speed), network or process details, required interfaces and mounting type (DIN rail, panel, cabinet), we will recommend suitable 3-phase meters, panel instruments, transmitters, tachometers or limit switches – and if required, a complete, well-matched package for your plant.

    Our Brands:

    Industrial measurement technology for machines and processes

    Industrial measurement technology comprises instruments, sensors and transmitters used to monitor and control machines, plants and energy systems. This category includes 3-phase power meters, panel instruments, tachometers, limit switches and transmitters for current, voltage, temperature, pressure and other process variables.

    Energy and power measurement

    Three-phase power meters and analyzers measure currents, voltages, active and reactive power and harmonics. They support energy optimization, load monitoring and power quality analysis in industrial installations.

    Panel instruments and displays

    Panel meters and process indicators display measured values directly in control panels or operator stations. They offer scalable inputs, alarm relays and interfaces for integration into control systems.

    Transmitters and limit switches

    Transmitters convert sensor signals into standardized current or voltage outputs and simplify connection to PLCs and SCADA systems. Limit switches monitor threshold values and trigger alarms or control actions when limits are exceeded.

    Industries and applications

    Typical applications include machinery and plant engineering, power generation and distribution, chemical and process industries, building automation and water/wastewater treatment.

    Benefits of professional industrial instrumentation

    Professional devices provide high accuracy, long-term stability and robust designs for harsh industrial environments. Flexible interfaces and configuration options facilitate integration into existing systems.