Transmitter for current, voltage, temperature & pressure – 4–20 mA / 0–10 V

Best sellers
SKU:
VT500-30-ff
Variations in:
  • Supply Voltage:
VT 500-30-, AC Voltage Transmitter
SKU:
UT125M
  • Transmitter for electrical signals
  • Universal input for standard signals, Pt100, thermocouple, potentiometer, configuration via front-side DIP switch
  • Analog output 4-20 mA
  • With Pt100 sensors, monitoring of sensor break and short-circuit
  • Wide-range power supply
  • Housing width 12.5 mm
  • Removable coded screw terminals
  • Carrier rail mounting TS35 EN60715
  • 171,36 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    ST500-10-5
    Item weight:
    0,11 kg
  • Supply voltage range: 10.8 ... 30V AC/DC
  • Electrically isolated: between input / output / supply voltage
  • 22.5 mm standard case for rail mounting TS35
  • Universal inputs/outputs for (0)4 ... 20 mA and 0(2) ... 10 V
  • 290,36 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    ST500-10-0
    Item weight:
    0,11 kg
  • Wide supply voltage range: 100 ... 265V AC
  • Electrically isolated: between input / output / supply voltage
  • 22.5 mm standard case for rail mounting TS35
  • Universal inputs/outputs for (0)4 ... 20 mA and 0(2) ... 10 V
  • 290,36 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TV125L
  • safe galvanic isolation between input/output/auxiliary voltage
  • step response T90: 40ms
  • output deviation <0.2% of the limit value
  • overload protection of the current input with automatically resetting fuse
  • operating display and status messages via two-colour LED
  • configuration via front DIP switches
  • plug-in terminal strips
  • slim installation width of 12.5mm for carrier rail mounting TS 35
  • 130,90 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    UNICON-P-1-1-3-00
    UNICON‑P pressure transmitter – programmierbar, präzise, robust (IP65)
    840,62 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TW500ff
    Variations in:
    • Channels
    Item weight:
    0,13 kg
  • 1, 2 or 3 channels
  • High protection acc. German VDE 0110 group 2
  • High accuracy
  • Low voltage drop
  • 22.5mm case for DIN rail mounting
  • SKU:
    TV500L-200-5
    • Galvanische Trennung zwischen input/output/Hilfsspannung
    • Eingänge: ±20mA and ± 10V DC
    • output: -20...+20mA and -10...+10VDC
    • steigende Kennlinie
    • Hilfsspannung: 230VAC
    • Betriebsanzeige durch LED
    • 22,5mm Normgehäuse for Tragschienenmontage
    SKU:
    TV500L-110-0
    Item weight:
    0,15 kg
    • full 3-port isolation
    • input: 0/4...20mA and 0/2...10VDC
    • output -20...+20mA and +10...+10VDC
    • increasing output characteristic
    • supply voltage: 230VAC
    • power-on LED
    • 22,5mm case for DIN rail mounting
    Best sellers
    SKU:
    TV500L-110-5
    Item weight:
    0,15 kg
    • full 3-port isolation
    • input: 0/4...20mA and 0/2...10VDC
    • output -20...+20mA and +10...+10VDC
    • increasing output characteristic
    • supply voltage: 24VDC
    • power-on LED
    • 22,5mm case for DIN rail mounting
    SKU:
    TS500-Ex-2R-5
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Inputs intrinsically safe acc. to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD]
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contact>
  • Supply voltage 24VDC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 197,54 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-Ex-2R-0
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Inputs intrinsically safe acc to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contacts
  • Supply voltage 230 VAC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 197,54 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-Ex-1R-5
  • Input for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Input intrinsically safe acc to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD]
  • Switchable line fault detection for broken and shorted lines
  • Output relay SPDT contact
  • Supply voltage 24VDC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 178,50 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-Ex-1R-0
  • Input for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Input intrinsically safe acc. to ATEX II (1) G [Ex ia] IIC/IIB, ATEX II (1) D [Ex iaD]
  • Switchable line fault detection for broken and shorted lines
  • Output relay SPDT contact
  • Supply voltage 230 VAC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 178,50 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-2R-5
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contact
  • Supply voltage 24VDC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 197,54 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-2R-0
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contact
  • Supply voltage 230VAC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 197,54 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-1R-5
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Switchable line fault detection for broken and shorted lines
  • Output relays SPDT contact
  • Supply voltage 24VDC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 170,17 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    TS500-1R-0
  • Inputs for switching contact, proximity switch Namur type acc. to DIN EN 60947-5-6 or opto-coupler
  • Switchable line fault detection for broken and shorted lines
  • Output relay SPDT contact
  • Supply voltage 230VAC
  • Power on LED, status / error LED
  • 22.5mm case for DIN rail mounting
  • 170,17 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    In stock
    SKU:
    TS125L-Ex-1-00
    • 1-channel version
    • Safe galvanic isolation between input / output / auxiliary voltage
    • Functional safety up to SIL2 EN61508
    • Inputs for switching contacts, Namur initiators or optocouplers
    • Intrinsically safe inputs for connecting sensors in Ex zones 0 and 20
    • Device installation i Ex zone 2 possible
    • Galvanic isolation according to reinforced insulation requirements (EN60664)
    • Switchable monitoring of the input circuit for wire breaks and short circuits
    • Relay output as NO contact (effect can be inverted)
    • Auxiliary voltage 24VDC
    • Configuration via DIP switches on the front
    • Pluggable coded terminal blocks
    • Housing width 12,5mm
    • DIN rail mounting TS35 EN60715
    • Operating display, switching status and error display by LEDs
    128,52 € *
    • Available
    • : 1 - 3 Workdays  (DE - int. shipments may differ)
    SKU:
    HD4V8T_ff
    Variations in:
    • Variant:
    Item weight:
    0,12 kg
    • Measuring range (depending on the variant): 10/20/50/200mbar, ±10/±20/±50/±200mbar
    • Relative pressure or differential pressure (depending on the variant)
    • Analog output: 0...5V, 1...5V, 0...10V (depending on the variant)
    • Protection class: IP67
    SKU:
    HD408T_ff
    Variations in:
    • Variant:
    Item weight:
    0,12 kg
    • Measuring range (depending on the variant): 10/20/50/200mbar, ±10/±20/±50/±200mbar
    • Relative pressure or differential pressure (depending on the variant)
    • Analog output: 4...20mA
    • Protection class: IP67
    SKU:
    MH-1Uff
    Variations in:
    • Auxiliary voltage
  • Transducer with universal input and analogue output
  • red LED display from -199...999 digits
  • digit height ca. 7 mm
  • min/max value recording
  • 9 adjustable supporting points
  • display flashing at treshold value exceedance / undercut
  • Tara function
  • programming interlock via access code
  • pluggable screw-terminal
  • further optional functions upon surcharge
  • SKU:
    MU125M
  • Universal input for Pt100, Pt1000, thermocouple, NTC and resistance measuring value
  • Configuration via front DIP switches
  • Analog actual value output 4-20mA
  • Zero point and limit value can be adjusted via trim potentiometers on the front
  • With Pt100 and Pt1000 sensors, monitoring of sensor break and short-circuit
  • Wide-range mains adapter: 20-125VDC snd 20-253VAC
  • Removable coded screw terminals
  • Housing width 12.5 mm
  • Carrier rail mounting TS35 EN60715
  • 188,02 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    Best sellers
    SKU:
    TC500-60-ff
    Variations in:
    • Supply Voltage:
  • suitable for thermocouples type J, K and S
  • integrated cold-junction compensation ;
  • sutput signal switch selectable
  • SKU:
    ST500Ex-10-5
    Item weight:
    0,12 kg
    Input intrinsically safe ATEX II (1) G [Ex ia] IIC, II (1) D [Ex iaD] 2 power-supply-designs with wide range of allowed supply voltage: 10 ... 30 V DC / AC oder 85 ... 253 V AC Electrically isolated: between input / output / supply voltage 22.5 mm standard case for rail mounting TS35 Universal inputs/outputs for (0)4 ... 20 mA and 0(2) ... 10 V
    347,48 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    SKU:
    ST500 Ex-10-0
    Item weight:
    0,12 kg
  • Input intrinsically safe ATEX II (1) G [Ex ia] IIC, II (1) D [Ex iaD]
  • 2 power-supply-designs with wide range of allowed supply voltage:
  • 10 ... 30VDC / AC oder 85 ... 253VAC
  • Electrically isolated: between input / output / supply voltage
  • 22.5 mm standard case for rail mounting TS35
  • Universal inputs/outputs for (0)4 ... 20mA and 0(2) ... 10V
  • 347,48 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    Best sellers
    SKU:
    RT500ff
    Variations in:
    • Supply Voltage
  • Resistance measuring range from 0 to 50 Ohm up to 100 kOhm 
  • 12 Bit AD/DA processor technology with 250Hz realtime execution 
  • Teach-in programming for initial and final value 
  • 2- and 3-wire connection
  • Outputs for 0/4-20mA, simultaneous 0/2-10V
  • Increase or decrease output characteristic programmable
  • Operation mode indicated by 2-colour LED
  • 22.5mm case for DIN rail mounting
  • SKU:
    PH40-2-2-00
    • Measuring range: -1 to +15 pH
    • Head transmitter for measuring chains with S7/S8 connector
    • Output: 4-20mA = -1 to +15 pH
    • Zero point: pH 7,0
    • Slope: 59.2 mV/pH, uncompensated
    309,40 € *
    • Available
    • : 11 - 13 Workdays  (DE - int. shipments may differ)
    Best sellers
    SKU:
    TV500P-2-100-00
    Passive Isolation amplifier TV500P, 2 channels, input: 4-20mA and 2-10VDC, outputs: 4-20mA passive, increasing characteristic
    SKU:
    P30Uff
    Variations in:
    • Variant
    • Universal measuring input, programmable
    • Input,  output signals and power supply galvanically isolated
    • Internal data memory for 534.336 samples
    • Output standard signal variants: 0/4-20mA
    • 2 Relay outputs
    • Supply voltage: 85-253VDC/85-300VDC
    You need help?
    Please send a message to priggen@priggen.com

    A signal transmitter (messumformer) converts a physical quantity (e.g. current, voltage, temperature, pressure, humidity, pH, conductivity) into a standardised output signal such as 4–20 mA or 0–10 V. This standard signal can then be processed safely and with low interference by PLCs, controllers or SCADA/building management systems.

    Our range includes transmitters for current and voltage (AC/DC, True RMS), AC current transmitters, frequency and pulse transmitters, pressure transmitters, temperature transmitters for Pt100/Pt1000, pH and conductivity transmitters as well as oxygen and humidity transmitters – many of them with galvanic isolation and freely scalable measuring ranges.

    Both provide standard analogue output signals. Transmitters with a 4–20 mA output are very immune to interference and cable resistance, which is why they are widely used in process industries. 0–10 V outputs are often used in building automation and applications with shorter cable runs. Many devices can be configured for either 4–20 mA or 0–10 V.

    Current and voltage transmitters measure AC or DC signals from loads, power supplies or measuring transformers and convert them into a standard output signal. Typical applications are energy and load monitoring, machine condition monitoring, supervision of electrical circuits and interfacing analogue electrical values to PLCs or control systems.

    Galvanic isolation electrically decouples input, output and supply circuits. This reduces interference, ground loops and the risk of dangerous voltages being transferred between circuits. Especially in systems with higher voltages, long cable runs or very sensitive input cards, transmitters with galvanic isolation are an important safety and quality feature.

    Pressure transmitters are used for example in HVAC and ventilation systems, filter monitoring, clean room applications, water and process plants and pneumatic systems. They convert relative or differential pressure into a 4–20 mA or 0–10 V signal, enabling continuous monitoring and control of pressure in your process.

    Start with the minimum and maximum process value you need to measure (e.g. temperature range, pressure range, current or voltage). The transmitter should cover this range safely without being oversized, to maintain good resolution. Then choose the output signal according to your system – typically 4–20 mA or 0–10 V. Many temperature and pressure transmitters offer configurable ranges and outputs via DIP switches or software.

    Yes. Because transmitters provide standard signals such as 4–20 mA and 0–10 V, they can usually be connected very easily to existing PLC, DCS or building management systems. You only need to check that the input ranges, supply voltage and any required galvanic isolation match your existing hardware.

    Yes, we offer various transmitters and signal isolators in Ex versions (for example temperature transmitters for Pt1000 or intrinsically safe signal isolators) that are approved for use in hazardous areas. Detailed information about approvals (e.g. ATEX, IECEx) is given in the data sheets of the respective products.

    Of course. If you tell us the measured variable, measuring range, medium, required output signal (4–20 mA or 0–10 V), installation conditions and any special requirements such as Ex protection or galvanic isolation, we will recommend suitable transmitters from our range. You can contact us by phone or e-mail via the contact details given in the shop.

    Our Brands:

    Signal conditioners for precise process signals

    Signal conditioners convert physical variables such as current, voltage, temperature, pressure, humidity, pH value or conductivity into standardized unit signals such as 4–20 mA or 0–10 V. These standardized signals can be transmitted with low interference to PLC, DCS or building management systems and evaluated or used for control there.

    In this category you will find a wide selection of industrial signal conditioners – from current and voltage signal conditioners to frequency and pulse signal conditioners, as well as pressure, temperature, pH, oxygen and conductivity signal conditioners with galvanic isolation for demanding applications in process and environmental measurement technology. :contentReference[oaicite:9]{index=9}

    Typical measured variables & designs

    • Signal conditioners for current and voltage (AC/DC, True RMS) for measuring currents and voltages in power distribution and plant monitoring.
    • AC signal conditioners for monitoring motors, drives and loads.
    • Frequency and pulse signal conditioners e.g. for speed, pulse counters or flow measurement.
    • Pressure signal conditioners for gauge and differential pressure, e.g. in ventilation, filtration and process systems.
    • Temperature signal conditioners for Pt100 / Pt1000 and thermocouples for signal conditioning of temperature sensors.
    • pH and conductivity signal conditioners for water and wastewater treatment, process water and environmental monitoring.
    • Oxygen and humidity signal conditioners for environmental, climate and indoor air applications.

    Standard signals 4–20 mA & 0–10 V

    Most devices in this category work with the unit signals established in automation technology: 4–20 mA and 0–10 V. These standardized output ranges simplify integration into existing control systems, enable long cable runs and reduce interference. Depending on the model, additional functions such as freely scalable measuring ranges, switching outputs, local displays or programmable limit values are available. :contentReference[oaicite:10]{index=10}

    Applications for signal conditioners

    Signal conditioners are used wherever measured values must be captured safely and reproducibly and converted into an evaluable signal, for example:

    • industrial process automation and plant monitoring,
    • building and HVAC systems,
    • energy metering and power monitoring,
    • water and wastewater technology, environmental and laboratory applications,
    • machine and plant engineering as well as test benches.

    Why buy signal conditioners from PSE Priggen?

    PSE – Priggen Special Electronic stands for proven signal conditioners from well-known manufacturers, competent technical advice and fast shipping within Germany, the EU and worldwide. In the Signal conditioners category of industrial measurement technology you will find suitable devices for new installations, retrofit projects and the replacement of existing signal converters.

    Not sure which signal conditioner (e.g. 4–20 mA or 0–10 V, current/voltage signal conditioner, pressure signal conditioner or temperature signal conditioner for Pt100/Pt1000) is right for your application? Our team will be happy to support you in selecting the right device.